Search results for "blue light"
showing 10 items of 22 documents
BLI (BLUE LIGHT IMAGING)™ SYSTEM FOR REAL-TIME HISTOLOGY PREDICTION OF SUBCENTIMETRIC COLORECTAL POLYPS
2018
Color choice behavior in cats and the effect of changes in the color of the illuminant.
1993
Luminescent PhotoCORMs: Enabling/Disabling CO Delivery upon Blue Light Irradiation.
2020
The new luminescent carbonyl compounds [Mn(Oxa-H)(CO)3Br] (1) and [Mn(Oxa-NMe2)(CO)3Br] (2) were synthesized and fully characterized. Complexes 1 and 2 showed CO release under blue light (λ453). Spectroscopic techniques and TD-DFT and SOC-TD-DFT calculations indicated that 1 and 2 release the Oxa-H and Oxa-NMe2 coligands in addition to the carbonyl ligands, increasing the luminescence during photoinduction.
Protective role of xanthophylls
2010
Xanthophylls, also known as carotenoids are a group of natural fat-soluble pigments that are especially abundant in green and yellow-orange fruits and vegetables. Based on epidemiologic data, it is now evident that carotenoids provide health benefits and particularly in eye diseases. Molecular characterization of retinal carotenoids has shown that there were actually two xanthophylls that are concentrated in macular region, namely lutein and zeaxanthin. Thanks to a strategic position within inner retinal layers, lutein and zeaxanthin are suspected to act as antioxidants in the retina in order to limit oxidative stress that results from metabolism of light. In addition, they are also suppose…
Blue-light imaging compared with high-definition white light for real-time histology prediction of colorectal polyps less than 1 centimeter: a prospe…
2019
Blue-light imaging (BLI) is a new chromoendoscopy technique, potentially useful for differentiating neoplastic from nonneoplastic lesions. The present study was aimed at comparing BLI with high-definition white light (HDWL) in the real-time histology prediction of colon polyps 10 mm.Consecutive outpatients undergoing colonoscopy with the ELUXEO 7000 endoscopy platform and 760 series video colonoscopes (Fujifilm Co, Tokyo, Japan) who had at least 1 polyp 10 mm were randomized to BLI or HDWL for polyp characterization. The accuracy of high-confidence real-time histology prediction (adenoma vs not adenoma) by either BLI or HDWL for polyps 10 mm (primary end-point) and diminutive (≤5 mm) polyps…
Increase in cortisol concentration due to standardized bright and blue light exposure on saliva cortisol in the morning following sleep laboratory
2020
Research studies on LED light exposure and cortisol are inconsistent and not comparable due to different types of light, exposure times, and sample sizes. Therefore, one hour of standardized exposure LED light at different intensities and the spectral composition during the post-awakening phase at 7:30 were compared. A sample of 23 (Study 1) and 26 (Study 2) healthy males were randomly assigned to: 1) bright white light (414 lux) and 2) dim darkened light (2 lux) as well as 3) red light (235 lux) and 4) blue light (201 lux) exposure conditions. Results from repeated measures ANOVA confirm that light exposure affects the cortisol concentration. Study 1 revealed an increase in the saliva cort…
Low-temperature growth of n ++-GaN by metalorganic chemical vapor deposition to achieve low-resistivity tunnel junctions on blue light emitting diodes
2018
We report on low-resistivity GaN tunnel junctions (TJ) on blue light-emitting diodes (LEDs). Si-doped n ++-GaN layers are grown by metalorganic chemical vapor deposition directly on LED epiwafers. Low growth temperature (<800 °C) was used to hinder Mg-passivation by hydrogen in the p ++-GaN top surface. This allows achieving low-resistivity TJs without the need for post-growth Mg activation. TJs are further improved by inserting a 5 nm thick In0.15Ga0.85N interlayer (IL) within the GaN TJ thanks to piezoelectric polarization induced band bending. Eventually, the impact of InGaN IL on the internal quantum efficiency of blue LEDs is discussed.
Blue light mediated C–H arylation of heteroarenes using TiO2as an immobilized photocatalyst in a continuous-flow microreactor
2017
Titanium dioxide was applied as an immobilized photocatalyst in a microstructured falling film reactor for the continuous-flow C-H arylation of heteroarenes with aryldiazonium salts as the starting material. Detailed investigations of the catalyst and a successful long-term run proved its excellent usability for this process. Very good yields up to 99% were achieved with broad substrate scope and were compared with batch synthesis. The transfer to the continuous-flow mode revealed an impressive boost in reactor performance solely resulting from the improved irradiation and contact of the catalyst, substrate and light.
Optimized blue light generation in optically contacted walk-off compensated RbTiOAsO4 and KTiOP1−yAsyO4
1999
Abstract We study type II 1.32 μm second harmonic generation (SHG) in a RbTiOAsO 4 optically contacted walk-off compensated device. The reduction of the effective walk-off angle by a factor of 3.7 with respect to KTiOPO 4 for the same interaction leads to an enhancement by a factor of 10 of the conversion efficiency. A model is proposed for both type I and type II SHG in such a structure. The angular tuning curve is a multi-peaked one, as predicted by the model. The enhancement of the SHG conversion efficiency allows us to optimize the generation of blue laser light at 440 nm: a specially designed KTiOP 0.98 As 0.02 O 4 solid solution crystal achieves angular non-critical phase matching at …
Zilo gaismu bloķējošo lēcu ietekme uz kontrastjutību
2018
Bakalaura darbs ir 21 lappaspusi garš, satur 9. attēlus, 1. tabulu un 39. literatūras atsauces. Darba mērķis ir novērtēt zilo gaismu bloķējošo lēcu ietekmi uz kontrastjutību. Mērījumi tika veikti, izmantojot Pelli-Robsona testu, kurš tika rādīts iPad telefonā. Mērījumā piedalījās 55 dalībnieki. Mērījumi tika veikti ar briļļu lēcām, kurām bija zilo gaismu bloķējošais klājums, kā arī ar lēcām, kurām bija tradicionālais pretatspīdumu klājums. Kontrastjutība bija labāka ar zilo gaismu bloķējošām lēcām nekā ar lēcām, kurām bija tradicionālais pretatspīdumu klājums (p<0.001). Dalībniekiem ar sūdzībām par žilbšanu kontrastjutības uzlabojums ar zilo gaismu bloķējošām lēcām bija lielāks nekā dalībni…